Download Data Sheet
EC400 Cat 6 F/UTP

Application Area
10Base-T, 100Base-T, 1000Base-T, and Fieldbus systems. Applicable for Power over Ethernet (PoE) / PoE+
Cable Construction
• 23 AWG Bare Copper 
• PE Insulation
• Pair Seperator
• Polyester Band
•Tinned Copper Drain Wire
• Al-Pet Foil 100% Coverage
• Ø 7.20 ± 0.20 mm PVC, LSZH or PE Jacket
Standards
EIA/TIA-568
ISO/IEC 11801 Class E
IEC 61156-5 , EN 50173-1
EN 50288-5-1
Technical Properties
Copper Weight 20.3 kg/km
Min. Bending radius    during draw in 60 mm
Min. Bending radius    permanently installed 30 mm
Max. Tensile Strength 90 N
Min. Crush Resistance 1000 N/10 cm
Min. Impact 10 Impacts
Installation Temperature 0°C … + 50°C
Operating Temperature -20°C … + 70°C
Packing 305 / 500 m
Electrical Properties                                       at 20ºC   
Max. Conductor Resistance < 9.5 Ω / km
Max. Resistance Unbalance < 2%
Min. Insulation Resistance 5000 MΩ x m
Mutual Capacitance < 60 pF / m
Max. Capacitance Unbalance 1600 pF / km
Impedance at 100 MHz 100 ± 5 Ω
Velocity of Propagation 66 %
Delay Skew < 45 ns / 100 m
Coupling Attenuation  > 55 dB 
Segregation Class C
Transfer Impedance at 1/10/30MHz  <50/100/200mΩ/m
Test Voltage 1000 V
Operating Voltage 125 V

Product Name

Euro Class

Cable Weight

Flame Retardancy

Corrosive Gases 

Smoke Density Download
Data Sheet
EC400 CAT 6 F/UTP PVC Eca Eca 62 Kg/Km EN 60332-1-2 N/A N/A Download
EC400 CAT 6 F/UTP LSZH Dca Dca 63 Kg/Km EN 60332-1-2 EN 50267-2-3 EN 61034-2 Download
EC400 CAT 6 F/UTP PE Fca Fca 54 Kg/Km N/A N/A N/A Download
Frequency 
(MHz)
Attenuation 
(dB/100 m)
NEXT
(dB)
PS - NEXT
(dB)
ACR
(dB/100 m)
PS-ACR
(dB/100 m)
ACRF
(dB/100 m)
PS-ACRF
(dB/100 m)
Return Loss
(dB)
1 2.0 83 80 85 82 83 80 25
4 3.6 73 70 70 67 70 67 31
10 6.0 73 70 65 62 60 57 30
100 19.5 55 52 40 37 35 32 25
200 28.5 50 47 25 22 30 27 22
250 32.0 45 42 25 22 22 19 22
300 33.0 40 37 15 12 20 17 22
400 39.0 40 37 7 4 20 17 20