RG11 U/4 Trishield AP
Cu/Al
Application Area
This type of RG11 cables is used for outdoor and aerial distributions of CATV networks and connections of SMATV systems which require low attenuations.
Cable Construction
|
Inner Conductor |
|
Ø 1.63 mm Bare Copper |
|
Insulation |
Ø 7.20 mm Gas Injected
Skin/Foam/Skin PE |
|
1st Shielding |
Aluminum Foil
Bonded to the insulation |
|
2nd Shielding |
|
Aluminum Wire Braiding |
|
3rd Shielding |
Aluminum Foil
Bonded to the Jacket |
|
Suspension Wire |
|
Ø 7x0.7 mm Galvanized Steel |
|
Outer Sheath |
|
Ø 10.00 - 15.50 mm PVC or PE |
Technical Properties
|
Copper Weight |
19 kg/km |
|
Min. Bending Radius |
65 mm |
|
Max. Tensile Strength |
200 N |
|
Operating Temperature |
-30 °C ... +70 °C |
|
Packing |
500 / 1000 m |
Electrical Properties
|
Impedance |
75+3 Ω |
|
Capacitance |
53 + 2 pF/m |
|
Velocity of Propagation |
84 + 2 % |
|
Insulation Resistance |
> 2 GΩxkm |
|
Operating Voltage |
2000 V |
|
Test Voltage |
5000 V |
|
Inner Conductor DCR |
< 8.50 Ω/km |
Attenuations (20°C)
|
5 MHz |
3.10 dB/100m |
|
50 MHz |
3.95 dB/100m |
|
230 MHz |
6.10 dB/100m |
|
470 MHz |
8.70 dB/100m |
|
860 MHz |
12.70 dB/100m |
|
1000 MHz |
14.00 dB/100m |
|
1200 MHz |
14.70 dB/100m |
|
2150 MHz |
21.80 dB/100m |
|
3000 MHz |
26.80 dB/100m |
Return Loss (20°C)
|
5-470 MHz |
> 26 dB |
|
470-1200 MHz |
> 23 dB |
|
1200-2000 MHz |
> 20 dB |
|
2000-3000 MHz |
> 18 dB |
Transfer Impedance
Screen Attenuation
|
30-1200 MHz |
≥ 85 dB |
|
1200-2000 MHz |
≥ 75 dB |
|
2000-3000 MHz |
≥ 65 dB
|
Standards
|
Screening Class |
Class A |
|
EN 50117-2-4 |
|
|
EN 50117-2-5 |
|
Product
Name |
Outer Sheath
Material |
Euro
Class |
Cable
Weight |
Flame
Retardancy |
Corrosive Gases
Test |
Smoke
Density |
Download
Data Sheet |
|
RG11 U/4 AP Cu/Al |
PVC |
Eca |
133 kg/km |
EN 60332-1-2 |
N/A |
N/A |
PVC |
|
RG11 U/4 AP Cu/Al PE |
PE |
Fca |
110 kg/km |
N/A |
N/A |
N/A |
PE |