Download Data Sheet
EC500 Cat 6A F/FTP

Application Area
10Base-T, 100Base-T, 1000Base-T, 10GBase-T, and Filedbus systems. Applicable for Power over Ethernet PoE / PoE+
Cable Construction
• 23 AWG Bare Copper 
• Skin/Foam/Skin PE Insulation
• Al-Pet Foil 100% Coverage
• Tinned Copper Drain Wire 
• Al-Pet Foil 100% Coverage
• Ø 7.50 ± 0.20 mm LSZH or PE Jacket
Standards
EIA/TIA-568
ISO/IEC 11801 Class EA
IEC 61156-5 , EN 50173-1
EN 50288-11-1
Technical Properties
Copper Weight 21.1 kg/km
Min. Bending radius    during draw in 60 mm
Min. Bending radius    permanently installed 30 mm
Max. Tensile Strength 95 N
Min. Crush Resistance 1000 N/10 cm
Min. Impact 10 Impacts
Installation Temperature 0°C … + 50°C
Operating Temperature -20°C … + 70°C
Packing 305 / 500 m
Electrical Properties                                       at 20ºC   
Max. Conductor Resistance < 9.5 Ω / km
Max. Resistance Unbalance < 2%
Min. Insulation Resistance 5000 MΩ x m
Mutual Capacitance < 56 pF / m
Max. Capacitance Unbalance 1600 pF / km
Impedance at 100 MHz 100 ± 5 Ω
Velocity of Propagation 76 %
Delay Skew 25 ns / 100 m
Coupling Attenuation  > 60 dB
Segregation Class C
Transfer Impedance 1/10/30 MHz < 10/10/30 mΩ/m
Test Voltage 1000 V
Operating Voltage 125 V
Product Name Euro Class Cable Weight Flame Retardancy Corrosive Gases  Smoke Density Download
Data Sheet
EC500 CAT 6A F/FTP LSZH Eca Eca 61 Kg/Km EN 60332-1-2 EN 50267-2-3 EN 61034-2 Download
EC500 CAT 6A F/FTP LSZH Dca Dca 61 Kg/Km EN 60332-1-2 EN 50267-2-3 EN 61034-2 Download
EC500 CAT 6A F/FTP PE Fca Fca 52 Kg/Km N/A N/A N/A Download
Frequency 
(MHz)
Attenuation 
(dB/100 m)
NEXT
(dB)
PS - NEXT
(dB)
ACR
(dB/100 m)
PS-ACR
(dB/100 m)
ACRF
(dB/100 m)
PS-ACRF
(dB/100 m)
Return Loss
(dB)
1 2.0 95 92 90 87 100 97 25
4 3.6 95 92 90 87 100 97 25
10 5.4 95 92 85 82 90 87 28
100 18.3 87 84 75 72 75 72 25
200 25.0 87 84 75 72 70 67 25
250 29.1 85 82 52 49 65 62 23
400 37.4 75 72 41 48 55 52 23
500 41.5 75 72 30 27 55 52 21