Mini Coax U/6
Cu/Cu
Class C
Application Area
This type of Mini Coax cables is used for indoor CATV distributions, and connections of SMATV systems which require low attenuations.
Cable Construction
Inner Conductor
Ø 0.65 mm Bare Copper
Insulation 
Ø 2.80 mm Gas Injected
Skin/Foam/Skin PE
1st Shielding
Cu-Pet Foil
2nd Shielding 
Annealed Copper Wire Braiding
Outer Sheath
Ø 4.40 mm PVC or HFFR*
Technical Properties
Copper Weight 9.4 kg/km
Min. Bending Radius 25 mm
Max. Tensile Strength 30 N
Operating Temperature -30 °C ... + 70 °C
Packing 100 / 300 / 500 m
Electrical Properties
Impedance 75+3 Ω
Capacitance 53 + 2 pF/m
Velocity of Propagation 82 %
Insulation Resistance > 2 GΩxkm
Operating Voltage 1000 V
Test Voltage 2500 V
Inner Conductor DCR < 61.90 Ω/km
Attenuations (20°C)
5 MHz 2.40 dB/100m
50 MHz 7.00 dB/100m
230 MHz 16.50 dB/100m
470 MHz 21.70 dB/100m
860 MHz 29.30 dB/100m
1000 MHz 31.95 dB/100m
1200 MHz 35.95 dB/100m
2150 MHz 48.50 dB/100m
3000 MHz 58.30 dB/100m
Return Loss (20°C)
5-470 MHz > 26 dB
470-1200 MHz > 23 dB
1200-2000 MHz > 20 dB
2000-3000 MHz > 18 dB
Transfer Impedance
5-30 MHz 50 mΩ/m
Screen Attenuation
30-1200 MHz ≥ 75 dB
1200-2000 MHz ≥ 65 dB
2000-3000 MHz ≥ 55 dB
 
Standards
Screening Class  
EN 50117-2-4  
Product
Name
Outer Sheath
Material
Euro
Class
Cable
Weight
Flame
Retardancy
Corrosive Gases
Test
Smoke
Density
Download
Data Sheet
Mini Coax U/6 Cu/Cu PVC Eca 24 kg/km EN 60332-1-2 N/A N/A PVC  
Mini Coax U/6 CuC/Cu  HFFR HFFR Dca 26 kg/km EN 60332-1-2 EN 50267-2-3 EN 61034-2 HFFR